Advanced Oxidation for Municipal Water Treatment

Meet regulatory limits, extend equipment life, and eliminate taste & odor complaints—while cutting energy and chemical costs by up to 60%.

NSF/ANSI 60 Certified Up to 84 mg/L Approved Potable Water Safe

Tightening Regulations, Aging Infrastructure

Municipal water treatment plants face mounting pressure from every direction: stricter DBP limits, aging ozone systems running beyond capacity, rising energy costs, and customer complaints about taste and odor.

Many facilities rely on ozone systems that are 20+ years old, requiring replacement investments of $10–50 million. Meanwhile, bromate, THM, and HAA5 levels continue to challenge regulatory compliance.

  • Bromate levels exceeding federal/state limits of 10 µg/L
  • Ozone generators running at 110%+ of rated capacity
  • Seasonal taste & odor complaints eroding public trust
  • Rising energy costs with flat or shrinking budgets
  • Capital replacement costs of $10–50M for aging systems
Green Water at Water Treatment Plant

The True Cost of Outdated Treatment

$10-50M
Ozone system replacement cost
110%+
Generator capacity strain at many plants
15+
Monthly T&O complaints (typical)
>10 µg/L
Bromate violations risking compliance
Water Treatment Plant

Hydroxyl-Radical Power, Simple Integration

HydroTreat™ uses proprietary mineral oxychloride (MxClyOz) technology to generate Reactive Oxygen Species—including hydroxyl radicals, the most powerful oxidizers known—that break down contaminants without forming harmful disinfection by-products.

Introduced at 8–10 mg/L into your raw water inlet or flash mixer, HydroTreat enhances coagulation, reduces ozone demand, and improves downstream treatment performance across your entire plant.

Unlike traditional pre-oxidants, HydroTreat delivers oxidation potential matching hydroxyl radicals (2.6–2.8 eV)—significantly higher than ozone (2.04 eV) or chlorine (1.36 eV).

In a 90-day field study, HydroTreat reduced ozone generator load from 110% to 40% of capacity within one hour of introduction—cutting energy consumption by 50–60%.

79.8%
Bromate reduction
50-60%
Energy savings
100%
HAA5 elimination
Zero
T&O complaints

Where HydroTreat Works

Simple addition to your existing treatment train with immediate, measurable results.

Raw Water Inlet
Flash Mixer
Pre-Ozonation
Coagulation Basin
Sedimentation
Filtration
Clearwell
Distribution System
Storage Tanks

Why Municipal Plants Choose HydroTreat

Dramatic Energy Savings

Reduce ozone generator load by 60–70%, cutting energy consumption by 50–60% while maintaining treatment efficacy.

📋

DBP Compliance

Achieve and maintain compliance with bromate, THM, and HAA5 limits—even with high-bromide source water.

🏗️

Capital Deferral

Extend the life of aging ozone systems by years, deferring $10–50M replacement projects.

🧪

Reduced Chemical Usage

40% reduction in chlorine demand at the clearwell, plus lower coagulant dosing requirements.

👃

T&O Elimination

Complete elimination of taste and odor complaints, restoring public confidence in water quality.

🔬

Enhanced Coagulation

70% improvement in settled water turbidity with denser floc formation and better settling.

🚛

Easier Solids Handling

Improved sludge dewatering and more efficient solids disposal from enhanced particle density.

🌿

Algae & Biofilm Control

No visible biofilm or algal growth in clarifiers and weirs throughout the treatment process.

NSF/ANSI 60 Certified

Approved for potable water applications up to 84 mg/L. Safe, compliant, and ready for municipal use.

90-Day Trial: 10 MGD Surface Water Plant

In a controlled study at a Northern California water treatment facility, HydroTreat™ was evaluated as a pre-oxidant at 8–10 mg/L. The plant had been struggling with bromate levels exceeding federal limits and an ozone system running beyond rated capacity.

Parameter Before After HydroTreat™ Improvement
Settled Water Turbidity (NTU) 0.70 0.21 +70.0%
Filtered Water TOC (mg/L) 2.2 1.1 +50.0%
Filtered Water NOM 0.044 0.017 +61.4%
Bromate (µg/L) 8.4 1.7 +79.8%
TTHMs (µg/L) 20.0 8.7 +56.5%
HAA5s (µg/L) 6.0 0 +100%
T&O Complaints (monthly) 15+ 0 Eliminated

Key Finding: Prior to the trial, monthly bromate levels averaged 18 µg/L—exceeding both state and federal limits of 10 µg/L. Within one hour of introducing HydroTreat™, bromate dropped below 1.0 µg/L and remained there for the duration of the study.

Oxidation Potential Comparison

HydroTreat™ delivers hydroxyl-radical-level oxidation power in a safe, stable formulation.

Oxidizing Reagent Potential (eV)
Hydroxyl Radical (OH⁻) 2.6–2.8
Mineral Oxychloride (HydroTreat™) 2.6–2.8
Ozone (O₃) 2.04–2.07
Permanganate (MnO₄) 1.67
Hypochlorous Acid (HOCl) 1.49
Chlorine Gas (Cl₂) 1.36
Chlorine Dioxide (ClO₂) 0.95

Ready to Improve Your Plant Performance?

Let’s discuss a pilot study at your facility. We’ll help you evaluate HydroTreat™ against your specific water quality challenges and regulatory requirements.

Talk to Our Team Read the Case Study